牛津仪器集团成员
扩展

Newton 971

Newton 971 - The most sensitive EMCCD spectroscopic detector ever offer you active pixels of 1600*400 alon with 16 x 16 µm Pixel size along with the -100°C TE cooling. It’s variable readout rates enable data readout at up to 3 Megahertz, through the plug and play USB interface.

  • EM sensor
  • Multi-Megahertz Readout
  • TE cooling to -100°C
  • UltraVac™
  • 16 x 16 μm pixel size


询价 增加到询价列表

EM technology enables charge from each pixel to be multiplied on the sensor before readout, providing single photon sensitivity. The Newton EM platform combines a 1600 x 200 (or 1600 x 400) array of 16 µm pixels, thermoelectric cooling down to -100°C for negligible dark current, 3MHz readout and USB 2.0 plug-and-play connectivity to provide unrivalled performance for spectroscopic applications. The dual output amplifiers allow software selection between either a conventional High Sensitivity or Electron Multiplying outputs to suit a broad range of photon regime conditions. This makes the Newton EMCCD the ideal choice for ultrafast chemical mapping applications e.g. SERS, TERS or luminescence mapping.

EM sensor technology - <1e- read noise

Fringe suppression technology as standard (970-BVF only) - Fringing minimized for NIR applications

Multi-Megahertz Readout - High repetition rates achievable with low noise electronics

TE cooling to -100°C - Negligible dark current without the inconvenience of LN2

UltraVac™ - Permanent vacuum integrity, critical for deep cooling

16 x 16 µm pixel size - Optimized pixel size for achievement of high resolution

Dual output amplifiers - Software select between either a conventional High Sensitivity output (for low light applications) or an Electron Multiplying output (for single photon sensitivity

Crop Mode Operation - Achieve the highest possible spectral rates of over 1,500 spectra per second

Simple USB Connection - USB connection direct from back of camera – no controller box required!

Solis software for Spectroscopy - Comprehensive, user-friendly interface for simultaneous detector & spectrograph control

Software Development Kit (SDK) - Ease of control integration into complex setups: Matlab, Labview, Visual Basic or C/C++

升级/配件

XW-RECR - Coolant re-circulator for enhanced cooling performance 

ACC-XW-CHIL-160 - Oasis 160 Ultra Compact Chiller Unit (tubing to be ordered separately) 

ACC-6MM-TUBING-2xxxxM - 6 mm tubing option for ACC-XW-CHIL-16 

LM-C - C-mount lens adaptor 

LM-NIKON-F - F-mount lens adaptor 

LMS-NIKON-F-NS25B - Nikon F-mount lens adaptor with shutter 

ACC-SD-VDM1000 - Shutter Driver for NS25B Bistable Shutter (not needed for Shamrock spectrographs) 

ACC-SHT-NS25B - Bistable Shutter, Standalone (not needed for Shamrock spectrographs) 

您可能想要…

相关应用

纳米材料生长和表征食品和土壤中污染物的鉴定化学和分子组成的测量泥土取证分析和其他痕量分析环境污染物分析材料成分和结构聚合物和聚合物相属性的测定低维结构表征光发射装置制造和表征模块化光学光谱催化材料表征食品安全质量控制与化学物质鉴定化学反应的原位观察模块化显微光谱学仿制药品