牛津仪器集团成员
扩展

iDus 1.7µm InGaAs

Andor iDus InGaAs 491 array series provide the most compact and optimized research-grade platform for Spectroscopy applications up to either 1.7 or 2.2 μm. The Thermo-Electrically cooled, in-vacuum sensors reach cooling temperatures of -90ºC where the best signal-to-noise ratio can be achieved for the majority of the applications in this spectral region.

  • 0.6 to 1.7 μm
  • Peak QE of > 85%
  • TE cooling to -90°C
  • UltraVac™
  • Single window design


询价 增加到询价列表

Andor's iDus InGaAs 1.7 array detector series provides the most optimized platform for Spectroscopy applications up to 1.7 µm. The TE-cooled, in-vacuum InGaAs camera sensors reach cooling temperatures of -90°C where best Signal-to-Noise ratio can be achieved. Indeed dark current will improve moderately below -90°C where scene black body radiation will dominate, while Quantum Efficiency of the sensor will be greatly impacted at these lower temperatures and lead to a lower Signal-to-Noise ratio.

0.6 to 1.7 µm - Operating wavelength range

Peak QE of > 85% - High detector sensitivity

TE cooling to -90°C - Negligible dark current without the inconvenience of LN2

UltraVac™ - Permanent vacuum integrity, critical for deep cooling and sensor performance

Single window design - Delivers maximum photon throughput

25 µm pixel width option - Ideal for high-resolution NIR spectroscopy

Simple USB 2.0 connection - USB plug and play – no controller box. Inputs & Outputs: External Trigger, Fire and Shutter TTL readily accessible. I2C for the more adventurous user

Software selectable output amplifiers - Allows user to optimize operation with choice of High Dynamic Range (HDR) or High Sensitivity (HS) modes of operation

Minimum exposure time of 1.4 µs - Enables higher time-resolution and minimization of dark current contribution for applications with reasonable signal level

升级/配件

XW-RECR - Coolant re-circulator for enhanced cooling performance 

ACC-XW-CHIL-160 - Oasis 160 Ultra Compact Chiller Unit (tubing to be ordered separately) 

ACC-6MM-TUBING-2xxxxM - 6 mm tubing option for ACC-XW-CHIL-160 

SR-ASZ-0033 - SR-750 Adapter Flange for InGaAs detector. 

SR1-ASZ-8044 - SR-163 Adapter Flange for InGaAs detector 

ACC-SD-VDM1000 - Shutter Driver for NS25B Bistable Shutter (not needed for Shamrock spectrographs) 

ACC-SHT-NS25B - Bistable Shutter, Standalone (not needed for Shamrock spectrographs) 

您可能想要…

相关应用

纳米材料生长和表征食品和土壤中污染物的鉴定化学和分子组成的测量环境污染物分析材料成分和结构监测和过程控制低维结构表征光发射装置制造和表征模块化光学光谱催化材料表征食品安全质量控制与化学物质鉴定化学反应的原位观察模块化显微光谱学
沪ICP备17031777号-1 公安机关备案号31010402003473